Merlin Gerin 685765 MCH-M Motor Mechanism - 125vDC MP Motor
Merlin Gerin
685 765 Merlin Gerin MCH-M Motor MechanismMerlin Gerin / Masterpact MP08 H1 Circuit Breaker 685-765Masterpact MP Charging Motor100/ 125 VDC*Are you...
View full details
685 765 Merlin Gerin MCH-M Motor MechanismMerlin Gerin / Masterpact MP08 H1 Circuit Breaker 685-765Masterpact MP Charging Motor100/ 125 VDC*Are you...
View full details0144D2112G001 / 0144D2112G002 General Electric Cell Rail SetLeft Hand Side PN: 0144D2112G001Right Hand Side PN: 0144D2112G002 For PowerVac VB / VB1...
View full detailsDS-632 Westinghoue DS-632 Air Framed Power Circuit BreakerClass A Reconditioned by NASElectrically OperatedDrawout3200 Amp Frame600 Volt3 Pole Retr...
View full details8258A34H01 Westinghouse 8258A34H01 Current Sensor*Unused Surplus in Box*800:5Current Rating 400A to 800AStyle: 8258A34H01 Each 8258A34H01 will be i...
View full details8346A28G11 ~ 8346A28G10 ~ 8346A28G09 Reconditioned Westinghouse DHP Test Set*Customer may need to add own rectifier for application* Each test set ...
View full details
708392T09 ITE 708392T09 K-Line Control RelayPN: 708392T09 , 708392-T09 , 708392T9 , 708392-T9120VAC Each used 708392T09 will be cleaned and teste...
View full detailsITE FB Circuit Breaker Secondary Disconnect PN: 703153K01
SHD16B216H GE PowerBreak II SHD16B216H Circuit BreakerCat#: SHD2C5F3U0508UHPowerBreak II Catalog BreakdownS - PowerBreak II BreakerH - High Break I...
View full details
K-1600 ITE K-1600 Circuit Breaker (Red or Black)ABB K-1600 Circuit Breaker Electrically Operated (Any Control Voltage)Drawout3 Pole1600 Amp Fram...
View full details432A671G2 General Electric AK circuit breaker 2-stage auxiliary switchAvailable Reconditioned or NewPN: 432A671G Each item will be inspected and te...
View full details
Shunt Trip Device for GE THED136100 Breaker 120VAC to 240 VAC 48 VDC to 125 VDC Coil: G9 Standard lead time (1-3) days prior to shipping if item is...
View full details
MDS630 EATON Magnum DS MDS630 Circuit BreakerCat#: MDS6303VEA 25MEC MNN2N NNNAX Magnum DS Catalog BreakdownMD - Magnum DS BreakerS - Standard Break...
View full details
MSRA Eaton Magnum Spring Release DeviceUnused SurplusStyle#: 2C12790G28Control Voltage: 110-127vAC 110-125vDCCoil: 2A10771G01Unused surplus no box...
View full details
MAUX2 Eaton Auxiliary Switch Style no.: 2C12791G01Cat no.: MAUX2 250 VAC - 10 Amp125 VDC - 1/2 Amp250 VDC - 1/4 Amp Each item will be inspected an...
View full details
Merlin Gerin Extension Handle Can be used with the following Merlin Gerin Insulated Case Circuit Breakers CM2500CM2500HECM2500HCM3200CM3200HECM3200...
View full details
AMC6EB GE AMC6EB Spectra Series Circuit Breaker Mounting Module300 Amp Max.600 V Max.6 PolesModel 1PN: AMC6EB Each used AMC6EB will be cleaned and...
View full details
AMC6QD GE AMC6QD Spectra Series Circuit Breaker Mounting ModuleModel 1450 Amp Max.240 V Max.6 PolesPN: AMC6QD Each used AMC6QD will be cleaned and...
View full details
DB-75 Westinghouse DB-75 Circuit Breaker3000 amp600 volt3 PoleElectrically OperatedDrawoutURC AC Pro Solid State Trip Unit or the Unit of Your Cho...
View full detailsPN: 184L701AUG12: Auxiliary switch for AK-2-25 / AK-2A-25 circuit breaker / choose NEW or Used/guaranteed 2 stage switch
PN: 269C273G2: Arc Quencher Clamp / AK-2-25 / AK-2A-25, available new or used
K-600 ITE/ABB K-600 Air Framed Power Circuit Breaker 600 Amp600 Volt3 PoleElectrically OperatedDrawoutMPS-C2000 Trip Unit ITE K-600 Power Circuit ...
View full details
AKR-5C-75 GE AKR-5C-75 Circuit Breaker3200 Amp 600 volt 3 pole Manually Operated AKR-5C-75 DrawoutCurrent Trip Unit SSTLSG568B604G60NAS can also...
View full details
3A73116G03 Key Interlock Provision Kit 3A73116G03Supply Bus Rating: 4000Section Bus Rating: 4000Neutral Bus Rating: 40003 Phase4 WireVolt: 480/ 277...
View full details
NMBP-01 ABB NMBP01 Modbus Plus Adapter Module SW Version 1.3 +24 VDC PN: NMBP-01 Each used NMBP-01 will be cleaned/ tested and backed by our 1 year...
View full details
Westinghouse DB-25 Mechanism 3 position Good Condition! Each used Westinghouse DB-25 Mech will be cleaned/ inspected prior to shipping. NASPG16350...
View full details
Save 100%
PN: 293B288G2: Arc Quencher / Arc Chute Used on General Electric circuit breakers: AK-2-25, AK-2A-25, AK-2-15, AK-2A-15, AKR-6D-30S, AKR-7D-30S, AK...
View full detailsPN: 293B288G2: Arc Quencher / Arc ChuteUsed on General Electric circuit breakers:AK-2-25, AK-2A-25, AK-2-15, AK-2A-15, AKR-6D-30S, AKR-7D-30S, AKR-...
View full details
168260A00 ABB 168260A00 Vacuum Bottles / Bottle Assemblies Each used 168260A00 will be cleaned, tested and backed by our 1 year warranty. Standard ...
View full details
Westinghouse DBF-6 Circuit Breakers600 volt600 Amp3-PositionElectrically OperatedDrawout3 PoleNAS can wire to your specifications. Ask about our R...
View full details
DB-50 Air Circuit Breaker Westinghouse DB-50 AirCircuit Breaker1600 Amp Frame600 volt3-PoleManually Operated or Electrically OperatedDrawoutURC AC...
View full details
GE Puffer Piston Canister for GE AM-5-250-1 Breaker 5 KV 1200 Amp Each used GE Puffer Piston Canister will be cleaned/ inspected prior to shipping....
View full details
GE Small Wheel for GE AM-5-250-1 Breaker 5 KV 1200 Amp Each used GE Small Wheel will be cleaned/ inspected prior to shipping. NASPG15793-1 , NASPG1...
View full details
GE Stationary Contact Assembly for GE AM-5-250-1 Breaker 5 KV 1200 Amp Each used GE Stationary Contact Assembly will be cleaned/ inspected prior to...
View full details
GE Blow Out Coil Cover Plate for GE AM-5-250-1 5 KV 1200 Amp Each used GE Blow Out Coil Cover Plate will be cleaned/ inspected prior to shipping. N...
View full details
GE Moving Contact Assembly for GE AM-5-250-1 5 KV 1200 Amp Please call or contact sales@naswgr.com for price on individual parts for this assembly....
View full details
GE Control Device for GE AM2.4/4.16-100/150 Breaker Each used GE Control Device will be cleaned/ inspected prior to shipping. NASPG15679-6 Loc...
View full detailsGE Limit Switch for GE AM2.4/4.16-100/150 Breaker Please contact sales@naswgr.com for more information.ch for GE AM2.4/4.16-100/150 will be Each...
View full detailsGE Small Wheel for GE AM2.4/4.16-100/150 Breaker 5 KV 1200 Amp Each used GE Small Wheel for GE AM2.4/4.16-100/150 Breaker will be cleaned/ inspecte...
View full details
GE Small Wheel for GE AM2.4/4.16-100-150 Breaker 5 KV 1200 Amp Each used GE Small Wheel for GE AM2.4/4.16-100-150 will be cleaned/ inspected prior ...
View full details
GE Arc Chute Blow Out Coil Cover Plate for GE AM2.4/4.16-100/150 Breaker 5 KV 1200 Amp Each used GE Arc Chute Blow Out Coil Cover Plate will be cle...
View full details
GE Moving Contact Assembly for GE AM2.4/4.16-100/150 Breaker GE Moving Contact Assembly5 KV1200 Amp Each used GE Moving Contact Assembly will be ...
View full details
6578509G2 GE 6578509G2 Auxiliary Switch for GE AM2.4/4.16-100/150 SB-12PN: 6578509G2 Each used 6578509G2 will be cleaned and inspected prior to ...
View full details
GE Stationary Contact Assembly for GE AM 2.4/4.16-100/150 Breaker 5KV 1200 Amp ed Each used GE Stationary Contact Assembly will be cleaned/ tested...
View full details
GE Small Wheel for GE AM-5-250-4 , 5 KV 1200 Amp Breaker Each used wheel will be inspected prior to shipping. NASPG15798-1 , NASPG15798-2 , NASPG1...
View full details
GE Stationary Contact Assembly for GE AM-5-250-4 Breaker 5 KV 1200 Amp Please Call or contact sales@naswgr.com for pricing on parts. Each used GE ...
View full details
GE Moving Contact Assembly for GE AM-5-250-4 Breaker 5 KV 1200 Amp Please call or contact sales@naswgr.com for pricing on parts! Each used GE Movin...
View full details
GE Arc Chute Blow Out Coil Cover Plate for GE AM-5-250-4 Breaker 5 KV 1200 Amp Each Arc Chute Blow Out Coil Cover Plate will be cleaned/ inspected...
View full details
18-657-346-579 Allis Chalmers LA-600 Electrically Operated Replacement CoverLA600LA-600 Front CoverAllis Chalmers LA-600 Front Cover E/OAllis-Chalm...
View full detailsCopyright © 2026 North American Switchgear Store.